NC1G-PE series
10/100/1000BASE-T to 1000BASE-X Media Converter (PoE Type)
NC1-PE Series Media Converter is media converter converting 10/100/1000BASE-T and 1000BASE-X mutually.
This product is equipped with 10/100/1000Mbps RJ45 port and 1000BASE-X SFP port.
This product operates by PoE power supply.
In addition, this product is equipped with the LFP (Link Fault Pass-through) function, and it helps to investigate the cause when a failure occurs.
Our lineup is of the following three types: 1000BASE-SX SFP mounted model, 1000BASE-LX SFP mounted model, Bi-directional 1G SFP (LC or SC) mounted model. And Bidi models are must use A type and B type in 1 pair.
Features
- 10/100/1000Mbps RJ45 port and 1000Mbps SFP port by one each.
- RJ45 port is support Auto-negotiation and Auto MDI/MDI-X
- Flow control for Full Duplex operation and back pressure for Half Duplex operation (IEEE 802.3x)
- Compliant with SFP MSA Specification SFF-8472
- 1000BASE-SX type is up to 550m with 50/125µm MMF
- 1000BASE-LX type and Bidi type are up to 15km with 9/125µm SMF
- Bidi type supports wavelength 1310nm (A type) and 1550nm (B type)
- Support for 1.25Gbps Bit Rate
- Simplex SC/LC Connector Interface
- Supports 9,216 bytes Jumbo Frames
- Supports 2,112 MAC address entries in entire system
- Supports LFP (Link Fault Pass-through) function
- Wire-speed packet filtering and forwarding rate
- Store-and-forward architecture filters fragment & CRC error packets
- EAP/ BPDU/ LACP/ LLDP/ IGMP and Tag Frame Pass through
- FAN less
- Class 1 laser product complies with EN 60825-1
- Temperature Range: 0~ 50 °C
- RoHS compliant
- Reliability compliant with Telcordia (Bellcore)
- GR-468-CORE
- Power supply via PoE(802.3af)
Spec
Models | NC1GS-PE | NC1GL-PE | NC1GL15B-PE |
NC1GL15B-SC-PE |
|
---|---|---|---|---|---|
Standards | IEEE802.3z, IEEE802.3ab, IEEE802.3u, IEEE802.3, IEEE802.3x, IEEE802.3af | ||||
Transmission speed | 10/100/1000Mbps (CSMA/CD) | ||||
Ethernet Ports |
10BASE-T/100BASE-TX/1000BASE-T (MDI/MDI-X Auto) | ||||
Duplex Auto Negotiation |
Full/Half 1000M/Full |
||||
Fiber ports | Transceiver | 1000BASE-SX (550m) | 1000BASE-LX (15km) | ||
Connector | LC Connector | SC Connector | |||
Duplex Auto Negotiation |
Full 1000M/Full |
||||
TX Wavelength | 850nm MMF | 1310nm SMF | A: 1310nm SMF B: 1550nm SMF |
A: 1310nm SMF B: 1550nm SMF |
|
Output | -9.5~-3dBm | ||||
Receiving sensitivity | -17~-0dBm | -20~-3dBm | -21~-3dBm | ||
Cable | standards | 10/100/1000BASE-T | 10/100/1000BASE-T 1000BASE-LX | ||
Cable used and Maximum distance |
UTP Cat.5e and over 100m 50/125μm MMF 550m 62.5/125μm MMF 275m | UTP Cat.5e 100m 9/125μm SMF 15km 10/125μm SMF |
|||
Function | Frame Transparent | link fault pass through (LFP) EAP/BPDU/LACP/LLDP/IGMP, Tag Frame Pass through |
|||
Transfer speed | Port Assignment | Store & Forward Method | |||
Maximum Frame Size | Jumbo Frame Size | 9,216bytes | |||
Through Put | 2.97Mpps(64byte) | ||||
Latency | 2.5μs (64byte) | ||||
Wire Speed | support | ||||
Buffer Architecture | Port Allocation | Dynamically allocated to each port | |||
Flash Memory | Capacity | 128K | |||
MAC Address Table | Method | Self-learning | |||
Aging Time | 300sec | ||||
Maximum MAC Address | 2,112 | ||||
LED Display | Power | Power On (Steady Green), Power Off (Off) | |||
LAN Link/Act | Valid port connection (Lighting) Data Transmitting / Receiving (Blinking) 1000Mbps: (Green), 10/100Mbps: (Orange) |
||||
Fiber Link/Act | Valid port connection (Lighting) Data Transmitting / Receiving (Blinking) 1000Mbps: (Green), 10/100Mbps: (Orange) |
||||
Power Supply / Energy Conservation |
Power Supply, Rated Input | 57VDC (IEEE802.3af, class0) | |||
Rated Maximum Input Current | 300mA or less | ||||
Maximum Power Consumption | 3W(Typ.2W) or less | ||||
Maximum Heat Generation | 2.236Kcal/h | ||||
General specification | Dimensions (W*D*H) | 75(W) × 101.2(D) ×22.6(H)mm (SFP not included) | |||
Weight | 200g (SFP not included) | ||||
Operation Temperature / Humidity | 0℃~+50℃ / 0%~90% *Non-condensing | ||||
Storage Temperature / Humidity | -20℃~+70℃ / 5%~90% *Non-condensing | ||||
Cooling systems | Fan-less | ||||
Adaptation of EMI | VCCI class A | ||||
Adaptation of RoHS | RoHS Directive Compliance | ||||
MTBF | 5,107,077h(25℃) | ||||
Accessories | Installation Guide & Warranty card x 1 |